Bild kan vara representation.
Se specifikationer för produktinformation.
P51-1000-S-S-M12-20MA-000-000

P51-1000-S-S-M12-20MA-000-000

Product Overview

Category

The P51-1000-S-S-M12-20MA-000-000 belongs to the category of industrial pressure sensors.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The sensor is typically packaged in a durable housing suitable for industrial environments.

Essence

The essence of the P51-1000-S-S-M12-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in demanding industrial settings.

Packaging/Quantity

The sensor is usually available as a single unit, packed securely to prevent damage during transportation and storage.

Specifications

  • Pressure Range: 0-1000 psi
  • Output: 4-20 mA
  • Electrical Connection: M12 connector
  • Operating Temperature: -40°C to 125°C
  • Pressure Type: Sealed gauge
  • Material: Stainless steel

Detailed Pin Configuration

The detailed pin configuration of the P51-1000-S-S-M12-20MA-000-000 includes the following: - Pin 1: Power supply - Pin 2: Ground - Pin 3: Signal output

Functional Features

  • High precision measurement
  • Compatibility with various media
  • Overpressure protection
  • Long-term stability
  • Easy integration into existing systems

Advantages and Disadvantages

Advantages

  • Accurate and reliable pressure measurements
  • Suitable for harsh industrial environments
  • Long-term stability ensures consistent performance
  • Easy to integrate into existing systems

Disadvantages

  • May require periodic calibration
  • Initial cost may be higher compared to some alternatives

Working Principles

The P51-1000-S-S-M12-20MA-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensing element, leading to a change in electrical resistance. This change is then converted into a proportional electrical signal, providing an accurate representation of the applied pressure.

Detailed Application Field Plans

The P51-1000-S-S-M12-20MA-000-000 is well-suited for a wide range of industrial applications, including: - Hydraulic systems - Process control - Industrial machinery - HVAC systems - Automotive testing

Detailed and Complete Alternative Models

Some alternative models to the P51-1000-S-S-M12-20MA-000-000 include: - P52-1500-S-S-M12-20MA-000-000 - P55-800-S-S-M12-20MA-000-000 - P60-2000-S-S-M12-20MA-000-000

In conclusion, the P51-1000-S-S-M12-20MA-000-000 is a high-precision industrial pressure sensor designed to meet the demands of various industrial applications, offering accurate and reliable pressure measurements in challenging environments.

[Word count: 456]

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-1000-S-S-M12-20MA-000-000 i tekniska lösningar

Sure, here are 10 common questions and answers related to the application of P51-1000-S-S-M12-20MA-000-000 in technical solutions:

  1. What is the operating range of P51-1000-S-S-M12-20MA-000-000?

    • The operating range of P51-1000-S-S-M12-20MA-000-000 is typically from 0 to 1000 psi.
  2. What type of output signal does P51-1000-S-S-M12-20MA-000-000 provide?

    • P51-1000-S-S-M12-20MA-000-000 provides a 4-20mA output signal.
  3. Can P51-1000-S-S-M12-20MA-000-000 be used in harsh environments?

    • Yes, P51-1000-S-S-M12-20MA-000-000 is designed to withstand harsh industrial environments.
  4. What is the accuracy of P51-1000-S-S-M12-20MA-000-000?

    • The accuracy of P51-1000-S-S-M12-20MA-000-000 is typically within ±0.25% of full scale.
  5. Is P51-1000-S-S-M12-20MA-000-000 suitable for use with corrosive media?

    • Yes, P51-1000-S-S-M12-20MA-000-000 is available with various wetted materials to handle corrosive media.
  6. What is the response time of P51-1000-S-S-M12-20MA-000-000?

    • The response time of P51-1000-S-S-M12-20MA-000-000 is typically very fast, allowing for real-time monitoring and control.
  7. Can P51-1000-S-S-M12-20MA-000-000 be integrated with PLC systems?

    • Yes, P51-1000-S-S-M12-20MA-000-000 can be easily integrated with PLC systems using its 4-20mA output signal.
  8. Does P51-1000-S-S-M12-20MA-000-000 require calibration?

    • P51-1000-S-S-M12-20MA-000-000 may require periodic calibration to maintain accuracy, depending on the application and environmental conditions.
  9. What is the temperature range for P51-1000-S-S-M12-20MA-000-000?

    • P51-1000-S-S-M12-20MA-000-000 is designed to operate within a wide temperature range, typically from -40°C to 85°C.
  10. Can P51-1000-S-S-M12-20MA-000-000 be used in mobile hydraulic applications?

    • Yes, P51-1000-S-S-M12-20MA-000-000 is suitable for use in mobile hydraulic applications due to its rugged construction and reliable performance.

I hope these answers are helpful! Let me know if you need further assistance.