Bild kan vara representation.
Se specifikationer för produktinformation.
P51-2000-S-I-MD-20MA-000-000

P51-2000-S-I-MD-20MA-000-000

Product Overview

Category

The P51-2000-S-I-MD-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure readings in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various industrial processes

Package

The P51-2000-S-I-MD-20MA-000-000 comes in a durable and protective packaging to ensure safe transportation and storage.

Essence

The essence of this product lies in its ability to accurately measure and transmit pressure data in challenging industrial environments.

Packaging/Quantity

The product is typically packaged individually and is available in single units.

Specifications

  • Pressure Range: 0-2000 psi
  • Output Signal: 4-20 mA
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel
  • Electrical Connection: M12 connector

Detailed Pin Configuration

The detailed pin configuration of the P51-2000-S-I-MD-20MA-000-000 is as follows: 1. Power Supply (+) 2. Power Supply (-) 3. Signal Output 4. Not Connected

Functional Features

  • Accurate pressure measurement
  • Linear output signal
  • Built-in temperature compensation
  • Overpressure protection

Advantages

  • Reliable and precise pressure readings
  • Suitable for harsh industrial environments
  • Easy integration into existing systems
  • Long-term stability

Disadvantages

  • Higher initial cost compared to some alternatives
  • May require specialized knowledge for installation and calibration

Working Principles

The P51-2000-S-I-MD-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal, which is then transmitted as a 4-20 mA output.

Detailed Application Field Plans

This pressure transmitter is suitable for a wide range of industrial applications, including: - Hydraulic systems - Process control - Industrial machinery - Oil and gas equipment - Water treatment plants

Detailed and Complete Alternative Models

Some alternative models to consider include: - P52-3000-S-I-MD-20MA-000-000 - P55-1500-S-I-MD-20MA-000-000 - P60-2500-S-I-MD-20MA-000-000

In conclusion, the P51-2000-S-I-MD-20MA-000-000 industrial pressure transmitter offers high accuracy, robustness, and reliability, making it a valuable component in various industrial settings.

[Word Count: 366]

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-2000-S-I-MD-20MA-000-000 i tekniska lösningar

  1. What is the application of P51-2000-S-I-MD-20MA-000-000?

    • The P51-2000-S-I-MD-20MA-000-000 is a pressure transducer commonly used in industrial and technical solutions to measure and monitor pressure in various systems.
  2. How does P51-2000-S-I-MD-20MA-000-000 work?

    • This pressure transducer works by converting pressure into an electrical signal, typically a 4-20mA output, which can be easily integrated into control systems for monitoring and automation.
  3. What are the typical industries that use P51-2000-S-I-MD-20MA-000-000?

    • Common industries include HVAC, automotive, aerospace, manufacturing, oil and gas, and process control, among others.
  4. What are the key features of P51-2000-S-I-MD-20MA-000-000?

    • Some key features include high accuracy, rugged construction, wide temperature range, and compatibility with various media types.
  5. How do I install and calibrate P51-2000-S-I-MD-20MA-000-000?

    • Installation involves mounting the transducer and connecting the electrical leads, while calibration may require adjusting the zero and span to match the desired pressure range.
  6. What are the environmental considerations for using P51-2000-S-I-MD-20MA-000-000?

    • It is important to consider factors such as temperature, humidity, and exposure to corrosive substances when installing the transducer in order to ensure accurate and reliable performance.
  7. Can P51-2000-S-I-MD-20MA-000-000 be used in hazardous environments?

    • Yes, there are versions of this transducer designed for hazardous locations, meeting specific safety standards such as ATEX or FM approvals.
  8. What maintenance is required for P51-2000-S-I-MD-20MA-000-000?

    • Regular inspection for damage, cleaning of the sensing element, and verifying calibration are common maintenance tasks to ensure continued accuracy and reliability.
  9. Are there any special considerations for wiring P51-2000-S-I-MD-20MA-000-000?

    • It is important to follow proper wiring practices, including shielding the signal wires and ensuring proper grounding to minimize electrical interference.
  10. Can P51-2000-S-I-MD-20MA-000-000 be integrated with PLCs or SCADA systems?

    • Yes, the 4-20mA output signal makes it compatible with a wide range of control and monitoring systems, including PLCs and SCADA, for seamless integration into larger industrial setups.