Bild kan vara representation.
Se specifikationer för produktinformation.
P51-50-S-U-MD-20MA-000-000

P51-50-S-U-MD-20MA-000-000

Basic Information Overview

Category

The P51-50-S-U-MD-20MA-000-000 belongs to the category of industrial pressure sensors.

Use

It is used for measuring and monitoring pressure in various industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with different media
  • Long-term stability

Package

The sensor is typically housed in a durable casing suitable for industrial environments.

Essence

The essence of the P51-50-S-U-MD-20MA-000-000 lies in its ability to provide precise and reliable pressure measurements in challenging industrial settings.

Packaging/Quantity

The sensor is usually packaged individually and may be available in bulk quantities as per the requirement.

Specifications

  • Pressure Range: 0-50 psi
  • Output: 4-20 mA
  • Operating Temperature: -40°C to 125°C
  • Pressure Type: Sealed Gauge
  • Material: Stainless Steel

Detailed Pin Configuration

The detailed pin configuration of the P51-50-S-U-MD-20MA-000-000 includes: - Pin 1: Power Supply (+) - Pin 2: Power Supply (-) - Pin 3: Signal Output - Pin 4: Not Connected

Functional Features

  • High precision pressure measurement
  • Compatibility with various media
  • Long-term stability and reliability
  • Compact and rugged design for industrial use
  • Easy integration into existing systems

Advantages and Disadvantages

Advantages

  • Accurate and reliable pressure measurements
  • Suitable for harsh industrial environments
  • Long-term stability
  • Wide operating temperature range

Disadvantages

  • May require periodic calibration
  • Initial cost may be higher compared to some alternatives

Working Principles

The P51-50-S-U-MD-20MA-000-000 operates on the principle of strain gauge technology, where the applied pressure causes deformation in the sensing element, leading to a change in resistance. This change is then converted into an electrical signal proportional to the pressure applied.

Detailed Application Field Plans

The P51-50-S-U-MD-20MA-000-000 is well-suited for various industrial applications, including: - Hydraulic systems - Pneumatic systems - Industrial machinery - Process control - HVAC systems

Detailed and Complete Alternative Models

Some alternative models to the P51-50-S-U-MD-20MA-000-000 include: - P51-100-S-U-MD-20MA-000-000 - P51-30-S-U-MD-20MA-000-000 - P51-75-S-U-MD-20MA-000-000 - P51-50-S-U-MD-10V-000-000

In conclusion, the P51-50-S-U-MD-20MA-000-000 is a robust and reliable industrial pressure sensor designed to meet the demanding requirements of various industrial applications. Its high precision, durability, and compatibility with different media make it a valuable component in industrial systems.

[Word Count: 464]

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-50-S-U-MD-20MA-000-000 i tekniska lösningar

Sure, here are 10 common questions and answers related to the application of P51-50-S-U-MD-20MA-000-000 in technical solutions:

  1. What is P51-50-S-U-MD-20MA-000-000?

    • P51-50-S-U-MD-20MA-000-000 is a specific model of pressure transducer used for measuring pressure in various technical applications.
  2. What is the operating range of P51-50-S-U-MD-20MA-000-000?

    • The operating range of P51-50-S-U-MD-20MA-000-000 is typically from 0 to 50 psi.
  3. What type of output signal does P51-50-S-U-MD-20MA-000-000 provide?

    • P51-50-S-U-MD-20MA-000-000 provides a 4-20 mA output signal, which is commonly used in industrial control systems.
  4. Is P51-50-S-U-MD-20MA-000-000 suitable for use in harsh environments?

    • Yes, P51-50-S-U-MD-20MA-000-000 is designed to be rugged and suitable for use in harsh industrial environments.
  5. What are the typical applications for P51-50-S-U-MD-20MA-000-000?

    • P51-50-S-U-MD-20MA-000-000 is commonly used in hydraulic systems, industrial machinery, and process control applications.
  6. Does P51-50-S-U-MD-20MA-000-000 require calibration?

    • Yes, P51-50-S-U-MD-20MA-000-000 should be calibrated periodically to ensure accurate pressure measurements.
  7. Can P51-50-S-U-MD-20MA-000-000 be used in high-temperature environments?

    • P51-50-S-U-MD-20MA-000-000 is available with options for high-temperature operation, making it suitable for such environments.
  8. What is the accuracy of P51-50-S-U-MD-20MA-000-000?

    • The accuracy of P51-50-S-U-MD-20MA-000-000 is typically within a certain percentage of the full-scale pressure range.
  9. Is P51-50-S-U-MD-20MA-000-000 compatible with different types of fluids?

    • P51-50-S-U-MD-20MA-000-000 is available with various wetted materials to ensure compatibility with different types of fluids.
  10. Are there any special installation considerations for P51-50-S-U-MD-20MA-000-000?

    • It's important to follow the manufacturer's guidelines for proper installation and mounting of P51-50-S-U-MD-20MA-000-000 to ensure accurate measurements and longevity.

I hope these questions and answers help provide clarity on the application of P51-50-S-U-MD-20MA-000-000 in technical solutions. Let me know if you need further assistance!