Product Overview

Category

The P51-500-A-E-M12-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure readings in various industrial applications.

Characteristics

  • High accuracy and reliability
  • Robust construction for harsh environments
  • Compatibility with different media types
  • Easy installation and maintenance

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage.

Essence

The essence of the P51-500-A-E-M12-20MA-000-000 lies in its ability to provide precise and consistent pressure measurements in industrial settings.

Packaging/Quantity

The product is usually sold individually, and the packaging may vary based on the supplier.

Specifications

  • Pressure Range: 0-500 psi
  • Output: 4-20mA
  • Electrical Connection: M12 Connector
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless Steel

Detailed Pin Configuration

The detailed pin configuration of the P51-500-A-E-M12-20MA-000-000 includes: - Pin 1: Power Supply (+) - Pin 2: Power Supply (-) - Pin 3: Signal Output - Pin 4: Not Connected

Functional Features

  • Accurate pressure sensing
  • Linear output proportional to pressure
  • Overpressure protection
  • EMC compliance for electromagnetic noise immunity

Advantages

  • Wide operating temperature range
  • High resistance to vibration and shock
  • Long-term stability
  • Easy integration with control systems

Disadvantages

  • Limited pressure range compared to some other models
  • Higher initial cost compared to basic pressure sensors

Working Principles

The P51-500-A-E-M12-20MA-000-000 operates on the principle of converting applied pressure into an electrical signal using a sensing element. This signal is then conditioned and transmitted as a 4-20mA output proportional to the pressure.

Detailed Application Field Plans

The P51-500-A-E-M12-20MA-000-000 is commonly used in industrial applications such as: - Hydraulic systems - Pneumatic systems - Process control - HVAC systems - Industrial machinery

Detailed and Complete Alternative Models

Some alternative models to the P51-500-A-E-M12-20MA-000-000 include: - P51-100-A-E-M12-20MA-000-000 (0-100 psi range) - P51-1000-A-E-M12-20MA-000-000 (0-1000 psi range) - P51-500-B-E-M12-20MA-000-000 (with different electrical connection)

This comprehensive entry provides a detailed overview of the P51-500-A-E-M12-20MA-000-000, covering its product details, specifications, functional features, advantages, disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-500-A-E-M12-20MA-000-000 i tekniska lösningar

  1. What is the P51-500-A-E-M12-20MA-000-000 sensor used for?

    • The P51-500-A-E-M12-20MA-000-000 sensor is commonly used for measuring pressure in various technical applications.
  2. What is the pressure range of the P51-500-A-E-M12-20MA-000-000 sensor?

    • The pressure range of the P51-500-A-E-M12-20MA-000-000 sensor is typically 0 to 500 psi.
  3. What type of output signal does the P51-500-A-E-M12-20MA-000-000 sensor provide?

    • The P51-500-A-E-M12-20MA-000-000 sensor provides a 4-20mA output signal, which is commonly used in industrial automation and control systems.
  4. Is the P51-500-A-E-M12-20MA-000-000 sensor suitable for use in harsh environments?

    • Yes, the P51-500-A-E-M12-20MA-000-000 sensor is designed to withstand harsh environmental conditions, making it suitable for a wide range of applications.
  5. What is the accuracy of the P51-500-A-E-M12-20MA-000-000 sensor?

    • The accuracy of the P51-500-A-E-M12-20MA-000-000 sensor is typically within ±0.5% of full scale, ensuring reliable and precise pressure measurements.
  6. Can the P51-500-A-E-M12-20MA-000-000 sensor be used with different media types?

    • Yes, the P51-500-A-E-M12-20MA-000-000 sensor is compatible with various media types, including gases and liquids.
  7. What is the operating temperature range of the P51-500-A-E-M12-20MA-000-000 sensor?

    • The P51-500-A-E-M12-20MA-000-000 sensor can operate within a temperature range of -40°C to 85°C, making it suitable for diverse environmental conditions.
  8. Does the P51-500-A-E-M12-20MA-000-000 sensor require calibration?

    • Yes, periodic calibration of the P51-500-A-E-M12-20MA-000-000 sensor is recommended to maintain its accuracy and performance over time.
  9. Can the P51-500-A-E-M12-20MA-000-000 sensor be integrated with PLCs or control systems?

    • Yes, the P51-500-A-E-M12-20MA-000-000 sensor's 4-20mA output signal allows for seamless integration with PLCs and various control systems.
  10. What are some typical applications for the P51-500-A-E-M12-20MA-000-000 sensor?

    • Typical applications for the P51-500-A-E-M12-20MA-000-000 sensor include hydraulic systems, pneumatic systems, industrial machinery, and process control.