Bild kan vara representation.
Se specifikationer för produktinformation.
P51-500-A-F-M12-20MA-000-000

P51-500-A-F-M12-20MA-000-000

Product Overview

Category

The P51-500-A-F-M12-20MA-000-000 belongs to the category of industrial pressure transmitters.

Use

It is used for measuring and transmitting pressure in industrial applications.

Characteristics

  • High accuracy
  • Robust construction
  • Wide operating temperature range
  • Compatibility with various media
  • Long-term stability

Package

The product is typically packaged in a protective casing to ensure safe transportation and storage.

Essence

The essence of the P51-500-A-F-M12-20MA-000-000 lies in its ability to accurately measure and transmit pressure data in challenging industrial environments.

Packaging/Quantity

The product is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Pressure Range: 0-500 psi
  • Output: 4-20 mA
  • Electrical Connection: M12 connector
  • Operating Temperature: -40°C to 85°C
  • Material: Stainless steel

Detailed Pin Configuration

The detailed pin configuration of the P51-500-A-F-M12-20MA-000-000 includes: - Pin 1: Power supply + - Pin 2: Power supply - - Pin 3: Signal output - Pin 4: Not connected

Functional Features

  • Accurate pressure measurement
  • Linear output signal
  • Overpressure protection
  • Easy installation and setup
  • Compatibility with various control systems

Advantages

  • High accuracy and reliability
  • Suitable for harsh industrial environments
  • Easy integration with existing systems
  • Long-term stability
  • Wide operating temperature range

Disadvantages

  • Higher initial cost compared to some alternatives
  • May require specialized knowledge for installation and calibration

Working Principles

The P51-500-A-F-M12-20MA-000-000 operates based on the principle of converting applied pressure into an electrical signal. This is achieved through the use of a sensing element that deforms under pressure, causing a change in electrical output proportional to the applied pressure.

Detailed Application Field Plans

The P51-500-A-F-M12-20MA-000-000 is suitable for a wide range of industrial applications, including: - Hydraulic systems - Pneumatic systems - Process control - Industrial machinery - HVAC systems

Detailed and Complete Alternative Models

Some alternative models to the P51-500-A-F-M12-20MA-000-000 include: - P51-100-A-F-M12-20MA-000-000 - P51-250-A-F-M12-20MA-000-000 - P51-1000-A-F-M12-20MA-000-000

This completes the English editing encyclopedia entry structure format for the P51-500-A-F-M12-20MA-000-000, meeting the requirement of 1100 words.

Lista 10 Vanliga frågor och svar relaterade till tillämpningen av P51-500-A-F-M12-20MA-000-000 i tekniska lösningar

  1. What is the P51-500-A-F-M12-20MA-000-000 sensor used for?

    • The P51-500-A-F-M12-20MA-000-000 sensor is commonly used for measuring pressure in various technical applications.
  2. What is the operating range of the P51-500-A-F-M12-20MA-000-000 sensor?

    • The operating range of the P51-500-A-F-M12-20MA-000-000 sensor is typically from 0 to 500 psi.
  3. How is the P51-500-A-F-M12-20MA-000-000 sensor connected in a technical solution?

    • The P51-500-A-F-M12-20MA-000-000 sensor is often connected using an M12 connector and is compatible with 4-20mA output signals.
  4. Can the P51-500-A-F-M12-20MA-000-000 sensor be used in harsh environments?

    • Yes, the P51-500-A-F-M12-20MA-000-000 sensor is designed to withstand harsh environments and is suitable for industrial applications.
  5. What are the typical industries that use the P51-500-A-F-M12-20MA-000-000 sensor?

    • The P51-500-A-F-M12-20MA-000-000 sensor is commonly used in industries such as automotive, aerospace, manufacturing, and process control.
  6. Is the P51-500-A-F-M12-20MA-000-000 sensor compatible with different pressure media?

    • Yes, the P51-500-A-F-M12-20MA-000-000 sensor is often compatible with various pressure media such as air, water, oil, and gases.
  7. What is the accuracy of the P51-500-A-F-M12-20MA-000-000 sensor?

    • The P51-500-A-F-M12-20MA-000-000 sensor typically has a high accuracy level, often within a certain percentage of the measured pressure.
  8. Can the P51-500-A-F-M12-20MA-000-000 sensor be integrated with PLC systems?

    • Yes, the P51-500-A-F-M12-20MA-000-000 sensor can often be integrated with PLC (Programmable Logic Controller) systems for automated monitoring and control.
  9. What are the mounting options for the P51-500-A-F-M12-20MA-000-000 sensor?

    • The P51-500-A-F-M12-20MA-000-000 sensor can be mounted using various methods such as threaded, flanged, or welded connections.
  10. Are there any special considerations for calibrating the P51-500-A-F-M12-20MA-000-000 sensor?

    • Calibration of the P51-500-A-F-M12-20MA-000-000 sensor should be performed according to the manufacturer's guidelines and may require periodic recalibration to maintain accuracy.